Product Description
The Laboratory Incubator Taisite FCI-30D is a forced-convection laboratory incubator designed to maintain a stable and uniform elevated-temperature environment for incubation, microbiological work, fermentation, sample testing and other controlled laboratory procedures.
The unit provides a 30-liter working chamber and a temperature setting range from approximately ambient temperature +5°C up to 80°C. A forced hot-air circulation system distributes heated air throughout the chamber to help minimize temperature differences between different locations inside the incubator.
The FCI series is described by Taisite distributors as laboratory incubators intended for applications including bacterial cultivation, fermentation and constant-temperature sample testing in pharmaceutical, biochemical, agricultural, industrial and research environments.
Unlike a natural-convection incubator, the FCI-30D uses forced convection. An internal air-circulation system moves heated air around the chamber to promote more even temperature distribution.
For the FCI-30D, the published temperature uniformity specification is ±1°C, with a temperature fluctuation of approximately ±0.5°C and a display/control resolution of 0.1°C.
Its compact 30L chamber makes the model suitable for laboratories that need controlled incubation capacity without the footprint of a large floor-standing unit.
Typical applications may include:
- Microbiology laboratories
- Pharmaceutical laboratories
- Biochemistry laboratories
- Medical and diagnostic laboratory support work
- Food and beverage testing laboratories
- Agricultural research
- Research institutions
- Educational laboratories
- Industrial quality-control laboratories
- Environmental laboratories
- Controlled-temperature sample studies
The suitability of the incubator for a particular test method should always be confirmed against the applicable SOP, test standard or laboratory protocol.
Key Features
The Taisite FCI-30D combines a compact chamber with forced air circulation and PID-based temperature regulation.
Key features include:
- 30-liter laboratory incubation chamber.
- Forced hot-air convection system.
- Ambient +5°C to 80°C operating temperature range.
- 1°C temperature resolution.
- Approximately ±0.5°C temperature fluctuation.
- Approximately ±1°C chamber temperature uniformity.
- PID temperature control system.
- PT100 temperature sensor.
- Digital temperature display.
- 0–9999 minute timer setting.
- Stainless-steel heating tube.
- 150W heating power.
- Mirror-finished stainless-steel interior.
- Corrosion-resistant coated steel exterior.
- Thermal insulation surrounding the chamber.
- Internal air-distribution design for improved temperature uniformity.
- Low-noise circulation design.
- Top exhaust/vent opening.
- Compact benchtop laboratory format.
- Adjustable/removable shelving configuration according to supplied unit.
- Up to 15 kg published load capacity per shelf.
- Suitable for routine laboratory incubation.
- Suitable for bacterial culture applications.
- Useful for fermentation studies.
- Suitable for constant-temperature sample testing.
- Appropriate for research and quality-control laboratories.
The published FCI-30D design uses forced circulation with vertical air guidance in models between 30L and 125L to support chamber temperature uniformity.
Technical Specifications
| Specification | Details |
| Product Name | Laboratory Incubator |
| Brand | Taisite / TaisiteLab Sciences Inc. |
| Model | FCI-30D |
| Product Code | 289 |
| Series | FCI |
| Chamber Capacity | 30 Liter |
| Convection | Forced Hot-Air Convection |
| Temperature Setting Range | Ambient +5°C to 80°C |
| Temperature Resolution | 0.1°C |
| Temperature Fluctuation | ±0.5°C |
| Temperature Uniformity | ±1°C |
| Temperature Controller | PID Control |
| Temperature Sensor | PT100 |
| Display | Digital |
| Timer | 0–9999 Minutes |
| Interior Material | Mirror-finished Stainless Steel |
| Exterior Material | Powder-coated Cold-Rolled Steel |
| Insulation Material | Aluminum Silicate Fiber |
| Heating System | Stainless-Steel Heating Tube |
| Heating Power | 0.15 kW / 150W |
| Exhaust Port | 1, located at top |
| Internal Dimensions | 310 × 310 × 310 mm |
| External Dimensions | Approx. 428 × 500 × 723 mm |
| Shelf Load | Up to 15 kg per shelf |
| Power Supply | AC 220V |
| Rated Current | Approximately 3.6A in published configuration |
| Supplied Shelves | Commonly 2 shelves |
| Country of Origin | China |
| Brand Association | TaisiteLab Sciences Inc. / USA |
The main chamber, thermal and dimensional specifications above are reported by a detailed Taisite distributor listing for the FCI-30D.
Another international distributor independently confirms the 30L capacity, forced convection and temperature range up to 80°C, while listing external dimensions of approximately 428 × 505 × 710 mm. Small dimensional differences can therefore occur between documentation or production versions.
Product Overview
30 Liter Chamber Capacity
The FCI-30D provides approximately 30 liters of internal chamber capacity.
Its published internal working dimensions are approximately:
310 × 310 × 310 mm
This compact chamber size can accommodate suitable Petri dishes, culture vessels, bottles, containers, test samples and other laboratory materials within the load and airflow requirements of the incubator.
The chamber should not be overloaded or packed in a way that blocks circulating air, because unrestricted airflow is important for maintaining temperature uniformity.
The 30L capacity is consistently identified for the FCI-30D across multiple international listings.
RT+5°C to 80°C Temperature Range
The FCI-30D is designed for temperatures above ambient.
Its specified setting range is:
Ambient Temperature +5°C to 80°C
For example, if laboratory ambient temperature is approximately 25°C, the practical minimum controlled operating temperature will normally be around 30°C rather than 25°C.
This is important because the FCI-30D does not incorporate refrigeration for operation below or close to ambient temperature.
Both Taisite distributor information and international FCI listings identify the range as approximately RT+5°C to 80°C.
Forced Convection System
The FCI series uses forced hot-air convection.
Rather than relying only on natural movement of heated air, the incubator actively circulates air throughout the chamber.
This helps:
- Distribute heat throughout the chamber.
- Reduce localized hot and cool areas.
- Improve temperature recovery.
- Maintain more consistent conditions between different shelf positions.
- Support laboratory processes requiring a stable controlled-temperature environment.
For the FCI-30D, the manufacturer-distributor specification gives a chamber temperature uniformity of approximately ±1°C.
PID Temperature Control
The incubator uses a PID temperature-control system according to published FCI-30D specifications.
PID control continuously responds to temperature changes and adjusts heating output to maintain the selected operating temperature more consistently than a simple on/off heating arrangement.
This is particularly useful for incubation processes where uncontrolled temperature variation could affect test conditions or sample behavior.
0.1°C Temperature Resolution
The published temperature resolution for the FCI-30D is:
0.1°C
This allows users to select and monitor temperature settings in small increments.
The resolution should not be confused with overall chamber accuracy or uniformity. The manufacturer’s distributor specification separately lists approximately ±0.5°C fluctuation and ±1°C uniformity.
PT100 Temperature Sensor
The FCI-30D is listed with a PT100 temperature sensor integrated into its temperature-control and safety system.
PT100 resistance temperature detectors are widely used in laboratory temperature-control equipment because they provide stable measurement across common laboratory temperature ranges.
The unit also includes an over-temperature alarm/safety arrangement according to published distributor specifications.
Digital Temperature Display
The FCI-30D provides digital temperature monitoring and adjustment.
One detailed Taisite distributor specification identifies an LED digital display, while another international listing describes the FCI-30D as LCD-equipped.
For Inaya Scientific’s product page, Digital Display is therefore recommended unless the stock unit is physically checked and the exact display type is confirmed.
0–9999 Minute Timer
Published specifications list a timer setting range of:
0–9999 Minutes
This can help laboratory operators run suitable incubation or heating procedures for a predetermined period.
Users should follow the actual supplied manual for timer behavior, especially whether timing begins immediately or after the chamber reaches the selected set temperature.
Stainless-Steel Internal Chamber
The internal chamber and shelving are described as mirror-finished stainless steel.
This construction provides a smooth laboratory working surface that is easier to clean than many untreated materials.
The exterior is described as cold-rolled steel with a corrosion-resistant powder coating.
Thermal Insulation
The chamber walls, top and door are thermally insulated to reduce heat transfer between the heated chamber and the external environment.
Published specifications identify aluminum silicate fiber as the insulating material.
Adequate insulation helps maintain chamber temperature while also reducing external surface heating.
150W Heating System
The FCI-30D uses a stainless-steel heating element system.
Published heating power is approximately:
0.15 kW = 150 Watts
The heating system works together with forced-air circulation and PID control to raise and maintain the chamber at the selected operating temperature.
Main Applications
Microbiology Laboratories
A controlled-temperature incubator is commonly required for microbiological incubation procedures.
Taisite’s FCI series is specifically marketed for bacterial culture and related laboratory incubation applications.
Actual incubation temperature, duration and sample-handling procedures should follow the laboratory’s validated method or SOP.
Bacterial Culture
The FCI series is described by distributors as suitable for cultivation of bacteria in controlled laboratory environments.
The forced-air system can help maintain comparatively uniform temperatures throughout the chamber during incubation.
Pharmaceutical Laboratories
Pharmaceutical laboratories may require controlled-temperature incubation during:
- Research work
- Sample preparation
- Microbiological testing
- Quality-control procedures
- Process-development studies
- Stability-related laboratory procedures where the specified temperature range is appropriate
Taisite distributors specifically identify pharmaceutical applications among the intended uses of the FCI series.
Biochemistry Laboratories
The unit may support suitable biochemical procedures that require samples to remain at an elevated controlled temperature for a defined time.
The actual method should be checked against the FCI-30D’s maximum temperature, uniformity and chamber specifications.
Fermentation Studies
Taisite distributor documentation lists fermentation among the typical applications of the FCI forced-convection incubator series.
The 30L chamber is particularly useful for small laboratory-scale work where large incubation capacity is unnecessary.
Agricultural Research
Agricultural and biological research laboratories may use controlled incubators for suitable experimental procedures requiring stable elevated temperature.
Agricultural research is specifically included among the stated application areas for the FCI series.
Educational Laboratories
Universities, colleges and technical institutions may use a laboratory incubator for:
- Microbiology practical work
- Biological experiments
- Culture demonstrations
- Research projects
- Sample incubation
- Controlled-temperature studies
The exact application should be supervised according to institutional laboratory procedures.
Food and Beverage Laboratories
Food-quality and microbiological laboratories may require incubation equipment during suitable culture or testing procedures.
The temperature and incubation conditions must always follow the applicable food-testing method or microbiological procedure.
Industrial Quality Control
Manufacturing and industrial laboratories may use controlled-temperature incubation for suitable samples during:
- Quality-control procedures
- Raw-material testing
- Process monitoring
- Product testing
- Research and development
The selected method must be compatible with the FCI-30D operating specifications.
Key Benefits
Uniform Temperature Distribution
Forced-air circulation helps distribute heated air around the chamber, while the published uniformity specification is approximately ±1°C.
Stable Temperature Control
PID control and a PT100 sensor provide the control architecture for maintaining the selected chamber temperature.
Compact 30L Chamber
The 30L size provides useful laboratory incubation capacity while remaining relatively compact for benchtop installation.
Wide Elevated-Temperature Range
The ambient +5°C to 80°C range supports many routine laboratory incubation and constant-temperature procedures.
Fine Temperature Resolution
A 0.1°C resolution allows controlled setting and digital monitoring of temperature.
Stainless-Steel Interior
The smooth stainless-steel interior supports routine cleaning and laboratory maintenance.
Programmable Time Setting
A timer of up to 9999 minutes provides additional control for suitable incubation procedures.
Laboratory-Friendly Design
The unit is designed for routine use in research, pharmaceutical, biochemical, microbiological and other scientific laboratory settings.
Who Should Buy This Product?
The Taisite FCI-30D 30L Laboratory Incubator may be suitable for:
- Microbiology laboratories
- Medical laboratories
- Diagnostic laboratory support sections
- Pharmaceutical companies
- Pharmaceutical QC laboratories
- Research laboratories
- Universities
- Colleges
- Medical colleges
- Science departments
- Food-testing laboratories
- Beverage-testing laboratories
- Agricultural research centers
- Biotechnology laboratories
- Biochemistry laboratories
- Industrial QC laboratories
- Research organizations
- Government laboratories
- Private laboratories
- Educational institutions
- Laboratory technicians
- Researchers
- Laboratory equipment procurement departments
Buyers should match the incubator’s temperature range, chamber capacity, uniformity and required documentation with their specific laboratory procedure before purchasing.
Usage and Operating Summary
Always follow the operating manual supplied with the actual FCI-30D.
A general laboratory workflow may include:
- Position the incubator on a stable, level and ventilated laboratory bench.
- Ensure adequate clearance around the ventilation openings.
- Confirm that the available power supply matches the incubator’s electrical rating.
- Inspect the chamber and shelves before loading samples.
- Arrange samples so that adequate air space remains around containers.
- Do not block the internal air-circulation path.
- Switch on the incubator.
- Set the required chamber temperature according to the laboratory SOP.
- Set the timer if required.
- Allow the chamber to stabilize before introducing temperature-sensitive samples where the procedure requires preheating.
- Minimize unnecessary door opening during incubation.
- Monitor operating temperature during the procedure.
- At the end of the process, remove samples using appropriate laboratory procedures.
- Allow the chamber to cool before cleaning where necessary.
- Clean and maintain the incubator according to the manufacturer’s instructions and laboratory SOP.
Sample Loading Considerations
Proper sample placement is important in a forced-convection incubator.
Avoid:
- Completely filling shelves.
- Blocking air passages.
- Placing samples directly against chamber walls.
- Overloading individual shelves.
- Using containers incompatible with the operating temperature.
- Allowing liquid spills to enter electrical or heating components.
Published information gives a maximum shelf load of approximately 15 kg per shelf for this configuration.
For best temperature distribution, samples should be positioned so circulating air can move around them.
Safety Considerations
- Read the manufacturer instructions before operation.
- Use only with the specified electrical supply.
- Ensure proper grounding.
- Position the equipment on a stable surface.
- Maintain ventilation space around the incubator.
- Do not block the exhaust port.
- Keep electrical components dry.
- Do not operate the incubator if the power cable or housing is damaged.
- Do not exceed the maximum specified temperature.
- Do not overload the shelves.
- Avoid blocking forced-air circulation.
- Wear appropriate PPE when handling biological, chemical or heated samples.
- Follow biosafety procedures for microbiological work.
- Do not incubate volatile, explosive or highly flammable substances unless the equipment is explicitly approved for that application.
- Use appropriate heat-resistant containers.
- Allow hot materials to be handled safely.
- Clean spills promptly using procedures suitable for the material involved.
- Disconnect electrical power before servicing where required.
- Do not modify electrical or temperature-control components.
- Keep the air outlet and ventilation areas unobstructed.
- Confirm calibration if the procedure requires traceable temperature accuracy.
Cleaning and Maintenance
Routine maintenance can help maintain reliable operation.
Internal Chamber
The mirror-finished stainless-steel chamber can be cleaned according to the laboratory’s approved cleaning procedure.
Before cleaning:
- Remove samples.
- Switch off the equipment.
- Disconnect power where required.
- Allow the chamber to cool.
Avoid allowing excessive liquid to enter fan, heater, sensor or electrical areas.

Shelves
Remove shelves when appropriate for cleaning.
Ensure shelves are dry and correctly positioned before reuse.
Door Seal
Inspect the door and sealing surfaces periodically for:
- Damage
- Dirt
- Deformation
- Poor closure
A compromised door seal may adversely affect heat retention and temperature stability.
Periodic Temperature Verification
Laboratories performing regulated or quality-controlled procedures should establish an appropriate temperature-verification or calibration schedule according to their own quality system.
Limitations and Important Considerations
- This is a heated incubator rather than a refrigerated incubator.
- Minimum operating temperature is approximately ambient +5°C.
- It cannot independently maintain temperatures below ambient.
- Maximum published setting temperature is 80°C.
- The chamber capacity is 30 liters.
- Temperature uniformity is listed as approximately ±1°C.
- Temperature fluctuation is approximately ±0.5°C.
- The displayed 0.1°C resolution does not mean the entire chamber is accurate to 0.1°C.
- Sample placement and airflow may influence chamber temperature distribution.
- Frequent door opening can disturb chamber temperature.
- The incubator should not be overloaded.
- Exact display type should be verified from the supplied stock unit.
- Exact external dimensions can differ slightly between distributor documentation.
- Included accessories should be confirmed before quotation.
- Required calibration certificates should be confirmed separately before institutional procurement.
- Users must follow laboratory-specific biosafety and sample-handling procedures.
International references consistently identify the FCI-30D as a 30L forced-convection incubator with an operating range reaching 80°C, but minor dimensional and display-description differences exist among supplier documentation.
Standard Supply / Package
A detailed distributor listing states a standard FCI-30D supply configuration including:
- 1 × Forced Convection Laboratory Incubator
- 2 × Sample Shelves
- 1 × Power Cable
- Operating documentation
The actual package supplied by Inaya Scientific should be checked before confirming accessories to a customer.
Available Configuration
Product: Laboratory Incubator
Brand: Taisite
Model: FCI-30D
Product Code: 289
Capacity: 30 Liter
Convection: Forced Air
Temperature Range: RT+5°C to 80°C
Resolution: 0.1°C
Temperature Fluctuation: ±0.5°C
Uniformity: ±1°C
Controller: PID
Sensor: PT100
Heating Power: 150W
Timer: 0–9999 Minutes
Pack Size: 1 Unit
Brand Association: USA
Country of Origin: China
Taisite FCI-30D Laboratory Incubator Price in Bangladesh
The latest Taisite FCI-30D Laboratory Incubator price in Bangladesh should be confirmed directly from Inaya Scientific.
As of August 2026, one current Bangladesh supplier listing shows the exact Laboratory Incubator 30L RT+5°C–80°C Force Convection FCI-30D Taisite USA at approximately ৳50,000 and marks the product as in stock.
This third-party market price should not be treated as Inaya Scientific’s selling price.
Actual price may vary depending on:
- Current import cost
- Supplier
- Exchange rate
- Product batch
- Included accessories
- Calibration requirement
- Warranty
- Documentation
- Order quantity
- Stock availability
- Delivery location
For an accurate quotation, request:
Taisite Laboratory Incubator – FCI-30D – 30L – RT+5°C to 80°C – Forced Convection – Product Code 289
Availability and Delivery in Bangladesh
The Taisite FCI-30D 30L Laboratory Incubator can be supplied by Inaya Scientific subject to current stock and import availability.
Customers requesting a quotation should provide:
- Required quantity
- Organization or customer name
- Delivery location
- Intended laboratory application
- Required calibration documentation, if applicable
- CO/COO requirement, if applicable
- Warranty requirement
- VAT/TAX documentation requirement, if applicable
- Delivery deadline
For institutional procurement, confirm:
- Brand
- Model
- Product code
- Chamber capacity
- Temperature range
- Temperature resolution
- Fluctuation
- Uniformity
- Controller type
- Sensor
- Heating power
- Internal dimensions
- External dimensions
- Shelf quantity
- Power requirement
- Country of origin
- Warranty
- Calibration requirement
- Documentation
- Current price
- Current stock
Why Buy From Inaya Scientific?
- Current Bangladesh price confirmation.
- Laboratory incubator sourcing support.
- Product specification verification.
- Institutional quotation assistance.
- University and research procurement support.
- Laboratory equipment supply support.
- Technical specification enquiry assistance.
- Bulk-order support.
- Scientific equipment sourcing.
- Microbiology laboratory equipment support.
- Pharmaceutical laboratory equipment sourcing.
- Educational laboratory equipment support.
- Related laboratory instruments and consumables sourcing.
- Nationwide delivery support subject to stock and courier conditions.
Frequently Asked Questions
1. What is the Taisite FCI-30D Laboratory Incubator?
The FCI-30D is a 30-liter forced-convection laboratory incubator designed to maintain a controlled elevated-temperature environment for suitable incubation, culture, fermentation and constant-temperature laboratory procedures.
2. What is the chamber capacity of the FCI-30D?
The chamber capacity is 30 liters. Multiple international listings independently confirm this capacity.
3. What is the temperature range?
The specified temperature setting range is approximately ambient temperature +5°C to 80°C.
4. Can the FCI-30D operate below room temperature?
No. It is a heated incubator without refrigeration. Its minimum controlled temperature is approximately room temperature plus 5°C.
5. What type of convection does it use?
The FCI-30D uses forced hot-air convection, meaning an internal airflow system circulates heated air throughout the chamber.
6. What is the temperature resolution?
The published temperature resolution is 0.1°C.
7. What is the temperature fluctuation?
The published temperature fluctuation is approximately ±0.5°C.
8. What is the temperature uniformity?
The published chamber uniformity is approximately ±1°C.
9. Does the FCI-30D use PID control?
Yes. Published specifications identify a PID temperature-control system.
10. What type of temperature sensor is used?
The model is listed with a PT100 temperature sensor.
11. Does the incubator have a timer?
Yes. Published specifications identify a timer range of 0–9999 minutes.
12. What is the heating power?
The listed heating power is approximately 0.15kW or 150W.
13. What is the internal chamber size?
The published internal chamber dimensions are approximately 310 × 310 × 310 mm.
14. What are the external dimensions?
One detailed distributor specification gives approximately 428 × 500 × 723 mm, while another international listing reports approximately 428 × 505 × 710 mm. The exact supplied unit should therefore be checked when dimensional clearance is critical.
15. Is the internal chamber stainless steel?
Yes. Published specifications describe the interior as mirror-finished stainless steel.
16. Can it be used for bacterial culture?
Taisite distributor documentation specifically lists bacterial culture among the common applications of the FCI incubator series. The actual incubation method, temperature and duration should follow the laboratory SOP.
17. Is the FCI-30D suitable for pharmaceutical laboratories?
Yes. Pharmaceutical and biochemical laboratory applications are among the intended areas identified for the FCI series.
18. Can it be used for fermentation?
Yes. Fermentation is specifically mentioned among the typical laboratory applications of the FCI forced-convection series.
19. Is Taisite FCI-30D made in the USA?
The brand is marketed as TaisiteLab Sciences Inc. / USA, while distributor documentation for this FCI-30D identifies the country of origin as China.
20. What is the Taisite FCI-30D price in Bangladesh?
A current Bangladesh listing in August 2026 shows approximately ৳50,000 for the FCI-30D. Inaya Scientific’s current selling price should be confirmed directly because market price, stock and import cost can change.
21. Where can I buy Taisite FCI-30D in Bangladesh?
Contact Inaya Scientific to confirm the latest stock, specification, institutional quotation and delivery availability for the Taisite FCI-30D 30L Laboratory Incubator.
Order From Inaya Scientific
Order the Laboratory Incubator 30L (RT+5°C to 80°C) Force Convection FCI-30D Taisite from Inaya Scientific for suitable microbiology, pharmaceutical, research, educational, agricultural and industrial laboratory applications.
Seller: Inaya Scientific
Product: Laboratory Incubator 30L Force Convection
Brand: Taisite / TaisiteLab Sciences Inc.
Model: FCI-30D
Product Code: 289
Capacity: 30 Liter
Temperature Range: Ambient +5°C to 80°C
Convection: Forced Air
Controller: PID
Pack Size: 1 Unit
Country of Origin: China
Mobile: +880 1778-492798
WhatsApp: 01620247815
Email: inayascientific@gmail.com
Delivery: Nationwide delivery across Bangladesh, subject to current stock and transport conditions.
When ordering, specify:
Taisite Laboratory Incubator – Model FCI-30D – Product Code 289 – 30 Liter – RT+5°C to 80°C – Forced Convection – 1 Unit







Reviews
There are no reviews yet.